CAS - CASR - CKSR

CAS:

Compact Fluxgate based current transducers single supplied (+5V).
3 primary pins.


CASR:

Compact Fluxgate based current sensors single supplied (+5V) with reference access 3 primary pins.

CKSR:

Compact Fluxgate based current transducers single supplied (+5V) with reference access 4 primary pins.
Higher creepage and clearance distances.
 

CAS - CASR - CKSR

CAS - CASR - CKSR

Main characteristics:

  • Low offset and gain drift
  • Measuring range up to 3 x IPN
  • 12 multi-range models ( 4 models for each type)
  • PCB mounting
  • Small AC&DC isolated current measurements from 1.5 to 50 ARMS nominal (6A, 15A, 25A and 50A models)
  • Compact design
  • Only 2.93 cm2 as PCB mounting area is needed to support the 9g of these transducers
  • High accuracy at +85°C:
    • CAS: 2.5 to 3% of IPN
    • CASR & CKSR: 1.2 to 1.8% of IPN

Features:

  • Isolation test voltage: up to 4.3KVRMS / 50 Hz / 1 min
  • Operating temperature range: -40°C to +85°C
  • Voltage output
  • Bandwidth DC to 300 KHz (+/- 3dB), 200KHz (+/- 1dB)
  • Fast response time <0.3µs
  • CASR & CKSR: Reference access on additional pin
  • CKSR: Different primary footprint with 4 pins for higher creepage and clearance distances (8.2 mm) for higher insulation
  • Each model is multi-range according to primary connection configuration