Technical data
Ouput Type : Conditioned
Measurement : Current
Technology : Prime
Application type : Analog transducer
Primary Nominal Valu * : 100 A, 150 A, 200 A
Primary Signal Type : AC
Bandwidth : AC, 30..6000 Hz
Accuracy : 1 %
Signal Conditioning Type: True RMS
Standard Output Typ ** : 0-5 VDC, 0-10 VDC
Primary configuration : Aperture
Aperture Dimension : ø 18 mm
Mounting : Panel, DIN rail
Power supply type : Loop Powered
* You can configure the measuring range (primary nominal value) by means of a switch, jumper or specific primary connection (depending the model)