Product Search
 

IT 150-600 S

< back

Made for high accuracy


Main characteristics:

  • Nominal current measurement: from 150 and 600 ADC
  • Excellent linearity: 1 ppm
  • High resolution
  • Initial offset: 20 ppm
  • Very low offset drift: 0.2 ppm/K
  • Overall accuracy @ IPN @ +25°C: < +/- 0.002 - 0.0096 %
  • Wide frequency bandwidth up to 100 kHz (+/- 3 dB)
  • 2 years warranty

Features:

  • DC, AC pulse currents' measurements with galvanic isolation
  • Fluxgate technology
  • Electrostatic shield between primary and secondary circuit
  • Power supply +/-15 Volt
  • Operating temperature range from +10 to +50°C
  • D-Sub 9 male interface output
  • Current output
  • Really quick response time (<250 ns)

Standard compliance:

  • European Directive EMC 2004 / 108 / EEC: CE Marking
  • Using UL94-VO recognized materials
  • Typical applications:
    • Feedback element in high performance gradient amplifiers for MRI
    • Feedback element in precision current regulated devices (power supplies…)
    • Precise and high stability inverters
    • Medical equipment
    • Energy measurement
    • Power analyzers
    • Calibration units

Remarks:

  • Current overload capability
  • Additional output indicating the transducer state
  • Under requirement and as an option, for very low noise current measurement or control, the internal zero flux detector frequency can be locked to an external frequency reference (35-45 kHz oscillator trigger signal) via an optional fibre optic input (HP-HFBR2521).
Product search results
Model Expand Primary
Nominal
Value
Measuring
Range
Secondary
Signal
Supply
Voltage (V)
Accuracy (%) Mounting
 
IT 150-S ULTRASTAB expand 150 A 150 A 200 mA 15-15 Bi 0.0088 Panel
  Technology : IT  
IT 600-S ULTRASTAB expand 600 A 600 A 400 mA 15-15 Bi 0.0022 Panel
  Technology : IT