Made for high accuracy
Main characteristics:
- Nominal current measurement: from 150 and 600 ADC
- Excellent linearity: 1 ppm
- High resolution
- Initial offset: 20 ppm
- Very low offset drift: 0.2 ppm/K
- Overall accuracy @ IPN @ +25°C: < +/- 0.002 - 0.0096 %
- Wide frequency bandwidth up to 100 kHz (+/- 3 dB)
- 2 years warranty
Features:
- DC, AC pulse currents' measurements with galvanic isolation
- Fluxgate technology
- Electrostatic shield between primary and secondary circuit
- Power supply +/-15 Volt
- Operating temperature range from +10 to +50°C
- D-Sub 9 male interface output
- Current output
- Really quick response time (<250 ns)
Standard compliance:
- European Directive EMC 2004 / 108 / EEC: CE Marking
- Using UL94-VO recognized materials
- Typical applications:
- Feedback element in high performance gradient amplifiers for MRI
- Feedback element in precision current regulated devices (power supplies…)
- Precise and high stability inverters
- Medical equipment
- Energy measurement
- Power analyzers
- Calibration units
Remarks:
- Current overload capability
- Additional output indicating the transducer state
- Under requirement and as an option, for very low noise current measurement or control, the internal zero flux detector frequency can be locked to an external frequency reference (35-45 kHz oscillator trigger signal) via an optional fibre optic input (HP-HFBR2521).
|