Product Search
 

ITC series

< back

Class accuracy R (Railway) current measurement up to 4000 ARMS

Main characteristics:

  • Non-invasive measurements of currents up to 4000 ARMS
  • Closed loop Fluxgate technology
  • Measuring range: up to 6000 ApK
  • Max overall accuracy: +/- 0.05 % of IPN at +25°C
  • Class 0.5 R according to EN50463
  • Max overall accuracy (+23°C):
    • +/- 0.2% of reading @ 10 % of IPN
    • +/- 0.4% of reading @ 5 % of IPN
    • +/- 2% of reading @ 1 % of IPN
  • Power Supply: +/- 21.6 to +/- 26.4 V
  • Operating temperature range: -40 to +85°C
  • Analogue current output: 0.8 & 1.6 A @ IPN for ITC 2000 & 4000 respectively
  • 5 year warranty
  • Reduced size & low power losses

Features:

 

  • DC, AC, pulse currents high accurate measurements with high galvanic isolation (isolation test voltage: 14 KVRMS / 50Hz / 1 min)
  • Aperture of 63 mm & 102 mm diameter for ITC 2000 & 4000 respectively
  • Really low current consumption: 150 mA & 300 mA @ IPN for ITC 2000 & 4000 respectively
  • Current overload: 100kA/100ms
  • Fast response time: 0,1µs
  • Large bandwidth: up to 80 KHz (3dB)
  • Low temperature drift of accuracy

 

 

Standards compliance:

 

  • EN50155 for traction applications such as:
    • On-board energy meters
    • Propulsion converters
  • EN 50124-1: Insulation levels & safety
  • NFF 16101/2: Fire and smoke classification
  • European Directive EMC 2004 / 108 / EEC : CE Marking
  • EN 50121-3-2: Railway EMC standard (Emission & susceptibility)
  • EN 50463: On-board energy measurement
  • EN 61010-1: Safety
  • Developed and produced according International Railway Industry Standards (IRIS)

 

Remarks:

 

  • New innovating patented technology for small current consumption
  • Modular approach for easy adaptation for secondary connections
  • Test winding as self test function
  • Logic additional output as indication of the transducer state
  • ITC 2000 is proposed in a split construction with the measurement head in a case and the measurement circuitry mounted remotely in a metal enclosure

 

Product search results
Model Expand Primary
Nominal
Value
Measuring
Range
Secondary
Signal
Supply
Voltage (V)
Accuracy (%) Mounting
 
ITC 2000-S/SP1 expand 2000 A 3000 A 800 mA 24-24 Bi 0.05 Panel
  Technology : Fluxgate  
ITC 4000-S expand 4000 A 6000 A 1600 mA 24-24 Bi 0.05 Panel
  Technology : Fluxgate