Energie & Automation
|
Courant nominal Plage de mesure IPN(A) |
Type de signal primaire |
Alimentation | Conditionnement de signal | Type de sortie | Montage | Séries |
| 5 - 150 | AC | self powered or loop powered | RMS |
0-5V / 0-10V 4 - 20 mA |
on primary fastening | AT |
| 2 - 5 | AC | 24 VDC | TRMS | 4 - 20 mA | Panel/ DIN* | AKR |
| 5 -200 | DC | 20 -50 V DC or 28-38V AC | 0 - 5 / 0 - 10 V 0 - 20 mA / 4 - 20 mA |
Panel / DIN* | DK | |
| 10 - 400 | AC | Loop powered or 24 V DC |
RMS | 0 - 5V / 0 - 10V 4 - 20mA |
Panel /DIN | AP |
| 10 - 400 | AC | Loop powered or 24 V DC |
TRMS | 0 - 5 V / 0 - 10V 4 - 20mA |
Panel / DIN | APR |
| 50-200 | AC & DC | 22 -38 V AC | 0 - 5 / 0 - 10V 0 - 20mA / 4 -20mA |
Panel / DIN* | DK | |
| 100 - 200 | AC | Self Powered or 24V DC loop powered (4 - 20mA) |
RMS | 0 - 5V / 0 - 10V | Panel / DIN* | AK |
| 100 - 100 | AC & DC | 20 - 50 V DC | TRMS | 0 - 5V / 0 - 10V 4 - 20mA |
Panel | DHR |
| 500 - 2000 | AC & DC | 20 - 50 V DC | TRMS | 0 - 5V / 0 - 10V 4 - 20mA |
Panel | AHR |
| 0.05 - 0.950 | AC | +/-24 V AC/DC | Capteurs de courant de fuite | Panel / DIN* | AKS | |
| 1 -200 | AC | Auto-alimenté | Panel / DIN* | AKS | ||
| 4 -100 | AC & DC | 20 - 28V AC/DC |
Panel / DIN* | DKS |
*Un adapteur peut être commandé séparément.