ART

Unique, IPx7, thin, light, flexible, split-core AC Rogowski Coil current sensor from 10 to 10000 ARMS with Class accuracy 0.5 according to IEC 61869 regardless of primary conductor position and rated insulation voltage 1kV CATIII.

Model details

ART-B22-D70/SP4

ART are calibrated & provided with a Class accuracy 0.5. ART needs an integrator at its output. Output voltage: 22.5 mV/kA. 70 mm aperture. Output cable length: 4.5m

Series
ART
Measurement
Current
Nominal Value
1000 A
Measuring Range
A
Second. Nominal Signal
Voltage
Second. Nominal Signal Value
Instantaneous V
Primary Signal
AC
Supply Voltage
Self Powered
Accuracy
0.5 %
Op. Temperature
-40 °C / 80 °C
Technology
Rogowski
Mounting
On primary fastening
Applications
Smart Grid
PICTURE
FRONT
BACK
LEFT
RIGHT
Order

Contact Information

Select any filter and click on Apply to see results
Series

Product of the same series

ART-B22-D125/SP25 3m, SMA

ART are calibrated & provided with a Class accuracy 0.5. ART needs an integrator at its output. Output voltage: 22.5 mV/kA. 125 mm aperture. 3 m output cable with SMA crimp plug.

ART-B22-D125/SP4

ART are calibrated & provided with a Class accuracy 0.5. ART needs an integrator at its output. Output voltage: 22.5 mV/kA. 125 mm aperture. Output cable length: 4.5m

ART-B22-D125/SP6

ART are calibrated & provided with a Class accuracy 0.5. ART needs an integrator at its output. Output voltage: 22.5 mV/kA. 125 mm aperture. Output cable length:6m

ART-B22-D175/SP3

ART are calibrated & provided with a Class accuracy 0.5. ART needs an integrator at its output. Output voltage: 22.5 mV/kA. 175 mm aperture. Output cable length: 3m

ART-B22-D175/SP4

ART are calibrated & provided with a Class accuracy 0.5. ART needs an integrator at its output. Output voltage: 22.5 mV/kA. 175 mm aperture. Output cable length: 4.5m

ART-B22-D175/SP6

ART are calibrated & provided with a Class accuracy 0.5. ART needs an integrator at its output. Output voltage: 22.5 mV/kA. 175 mm aperture. Output cable length: 6m

ART-B22-D300

ART are calibrated & provided with a Class accuracy 0.5. ART needs an integrator at its output. Output voltage: 22.5 mV/kA. 300 mm aperture.

ART-B22-D300/SP3

ART are calibrated & provided with a Class accuracy 0.5. ART needs an integrator at its output. Output voltage: 22.5 mV/kA. 300 mm aperture. Output cable length: 3m

ART-B22-D300/SP4

ART are calibrated & provided with a Class accuracy 0.5. ART needs an integrator at its output. Output voltage: 22.5 mV/kA. 300 mm aperture. Output cable length: 4.5m

ART-B22-D300/SP6

ART are calibrated & provided with a Class accuracy 0.5. ART needs an integrator at its output. Output voltage: 22.5 mV/kA. 300 mm aperture. Output cable length: 6m

ART-B22-D70/SP3

ART are calibrated & provided with a Class accuracy 0.5. ART needs an integrator at its output. Output voltage: 22.5 mV/kA. 70 mm aperture. Output cable length: 3m

ART-B22-D70/SP6

ART are calibrated & provided with a Class accuracy 0.5. ART needs an integrator at its output. Output voltage: 22.5 mV/kA. 70 mm aperture. Output cable length: 6m

ART-B22-D125

ART are calibrated & provided with a Class accuracy 0.5. ART needs an integrator at its output. Output voltage: 22.5 mV/kA. 125 mm aperture.

ART-B22-D175

ART are calibrated & provided with a Class accuracy 0.5. ART needs an integrator at its output. Output voltage: 22.5 mV/kA. 175 mm aperture.

ART-B22-D70

ART are calibrated & provided with a Class accuracy 0.5. ART needs an integrator at its output. Output voltage: 22.5 mV/kA. 70 mm aperture.