LESR

Closed Loop Hall effect Performing at the level of Fluxgate technology without the added cost, Low offset drift 3 to14 ppm/°C, -40°C to + 105°C,  Reference access, Primary integrated conductors , 100 % fully compatible with CASR xx-NP series

Model details

LESR 15-NP

15 A nominal, C/L Hall effect Performing at the level of Fluxgate technology without the added cost, Low offset drift 6 ppm/°C, -40°C to + 105°C,  Reference access, Primary integrated conductors , 100 % fully compatible with CASR 15-NP

Series
LESR
Measurement
Current
Nominal Value
15 A
Measuring Range
51 A
Second. Nominal Signal
Voltage
Second. Nominal Signal Value
Instantaneous 2.5 +/- 0.625 V
Primary Signal
AC + DC
Supply Voltage
External DC Unipolar
Accuracy
0.5 %
Op. Temperature
-40 °C / 105 °C
Technology
Closed loop Hall effect
Mounting
PCB
Applications
Drives
Power Supplies
Renewable Energies
Welding
LESR 15-NP
PICTURE
FRONT
BACK
LEFT
RIGHT
Download

Relative information

Order

Contact Information

Series

Product of the same series

LESR 6-NP/SP1

6 A nominal, C/L Hall effect Performing at the level of Fluxgate technology without the added cost, Low offset drift 14 ppm/°C, -40°C to + 105°C,  Reference access, Only 2 integrated primary conductors for differential measurement with 1 turn

LESR 50-NP/SP1

50 A nominal, C/L Hall effect Performing at the level of Fluxgate technology without the added cost, Low offset drift 3 ppm/°C, -40°C to + 105°C,  Reference access, Only 4 integrated primary conductors for differential measurement with 2 x 2 turns

LESR 25-NP/SP1

25 A nominal, C/L Hall effect Performing at the level of Fluxgate technology without the added cost, Low offset drift 4 ppm/°C, -40°C to + 105°C,  Reference access, Only 4 integrated primary conductors for differential measurement with 2 x 2 turns

LESR 15-NP/SP1

15 A nominal, C/L Hall effect Performing at the level of Fluxgate technology without the added cost, Low offset drift 6 ppm/°C, -40°C to + 105°C,  Reference access, Only 2 integrated primary conductors for differential measurement with 1 turn

LESR 6-NP

6 A nominal, C/L Hall effect Performing at the level of Fluxgate technology without the added cost, Low offset drift 14 ppm/°C, -40°C to + 105°C,  Reference access, Primary integrated conductors , 100 % fully compatible with CASR 6-NP

LESR 25-NP

25 A nominal, C/L Hall effect Performing at the level of Fluxgate technology without the added cost, Low offset drift 4 ppm/°C, -40°C to + 105°C,  Reference access, Primary integrated conductors , 100 % fully compatible with CASR 25-NP

LESR 50-NP

50 A nominal, C/L Hall effect Performing at the level of Fluxgate technology without the added cost, Low offset drift 3 ppm/°C, -40°C to + 105°C,  Reference access, Primary integrated conductors , 100 % fully compatible with CASR 50-NP