LV100xx

Closed Loop Hall effect technology. DC, AC pulse voltage' measurements of 100 to 4000 VRMS nominal with galvanic isolation.To be panel mounted.

Model details

LV 100-1000

1000 VRMS nominal.

Series
LV100xx
Measurement
Напряжение
Nominal Value
1000 V
Measuring Range
1500 V
Second. Nominal Signal
Ток
Second. Nominal Signal Value
Мгновенное значение 50 mA
Primary Signal
Переменный + постоянный ток
Supply Voltage
Внешнее двухполярное постоянного тока
Supply Voltage Range
15 - 15 V
Accuracy
0.7 %
Op. Temperature
70 °C
Технология
Компенсационные на основе эффекта Холла
Mounting
На панель
Применения
Приводы
Системы электропитания
Возобновляемые источники энергии
Транспорт
Сварка
PICTURE
FRONT
BACK
LEFT
RIGHT
Скачать

Relative information

Заказ

Контактная информация

Серии

Изделия этой серии

LV 100-5000/SP1

5000 VRMS nominal. +/- 15 to 24V +/- 10% power supply, -45°C to +85°C, Isolation test voltage 12kVRMS/50 Hz/1 min, Primary and secondary connections on M5 threaded studs, Shield, For traction.

LV 100-4000/SP6

4000 VRMS nominal. +/- 15 to +/- 24 V power supply, 12 kVRMS isolation test voltage, -40°C to +85°C, Connection to primary by extra long studs, Secondary connections on M5 threaded studs, Shield, For traction.

LV 100-1000/SP13

1000 VRMS nominal. +/- 16 to 33 V power supply, 12 kVRMS as isolation test voltage, -25°C to +70°C, For traction.

LV 100-1000/SP16

1000 VRMS nominal. +/- 15 to +/- 24 V power supply, -25°C to +70°C, Secondary connections on M5 threaded studs, For traction.

LV 100-1000/SP9

1000 VRMS nominal. +/- 15 to +/- 24 V power supply, -40°C to +70°C, Primary and secondary connections on M5 threaded studs, For traction.

LV 100-1500/SP3

1500 VRMS nominal. +/- 15 to +/- 24 V power supply, -40°C to +85°C, Secondary connection on M5 threaded studs, For traction.

LV 100-2000/SP15

2000 VRMS nominal. +/- 15 to +/- 24 V power supply, 9 kVRMS isolation test voltage, -40°C to +75°C, Secondary connections on M5 threaded studs, Shield, For traction.

LV 100-2000/SP17

2000 VRMS nominal. +/- 15 to +/- 24 V power supply, -25°C to +80°C, Primary and secondary connections on UNC 10-24 threaded studs, Shield, For traction.

LV 100-2000/SP18

2000 VRMS nominal. +/- 15 to +/- 24 V power supply, 9 kVRMS isolation test voltage, -40°C to +70°C, Primary and secondary connections on M5 threaded studs, For traction.

LV 100-2000/SP5

2000 VRMS nominal. +/- 15 to +/- 24 V power supply, 9 kVRMS isolation test voltage, -25°C to +70°C, For traction.

LV 100-2000/SP6

2000 VRMS nominal. +/- 15 to +/- 24 V power supply, 12 kVRMS isolation test voltage, -40°C to +85°C, Secondary connections on M5 threaded studs, Shield, For traction.

LV 100-3000/SP12

3000 VRMS nominal. +/- 15 to +/- 24 V power supply, 12 kVRMS isolation test voltage, -40°C to +85°C, Secondary connections on M5 threaded studs, For traction.

LV 100-3000/SP3

3000 VRMS nominal. +/- 15 to +/- 24 V power supply, 12 kVRMS isolation test voltage, -25°C to +70°C, For traction.

LV 100-3500/SP2

3600 VRMS nominal. +/- 24 V power supply, -25°C to +70°C, For traction.

LV 100-4000/SP2

4000 VRMS nominal. +/- 15 to +/- 24 V power supply, -25°C to +70°C, For traction.

LV 100-500/SP6

500 VRMS nominal. +/- 15 to +/- 24 V power supply, -40°C to +70°C, Primary and secondary connections on M5 threaded studs, For traction.

LV 100-600/SP6

600 VRMS nominal. +/- 15 to +/- 24 V power supply, -40°C to +75°C, Secondary connections on M5 threaded studs, Shield, For traction.

LV 100-750/SP4

750 VRMS nominal. +/- 15 to +/- 24 V power supply, -40°C to +70°C, Primary and secondary connections on M5 threaded studs, Shield, without electrolytic capacitors, For traction.

LV 100-750/SP8

750 VRMS nominal. +/- 15 V power supply, -40°C to +80°C, Primary and secondary connections on M5 threaded studs, Shield, For traction.