Product Search
 


Nominal Current Range Ipn (Apn) Power Supply Range (V) Global Accuracy @ +25°C, % of Ipn Bandwidth (kHz) Mounting Technology Series
0.25 - 200 +/- 12...15 0.4 - 0.9% DC - 150 PCB C/L LA 25-200 -P
100 - 1000 +/- 15 1 - 1.35% DC - 50 Panel O/L HTA Traction
200- 500 +/- 12...24 0.6 - 0.9% DC - 100 Panel C/L LA 205 / 305 -S/ -T Traction
200 - 500 +/- 24 1% DC - 100 Split core C/L LA 200 / 500-SD
200 - 2000 +/- 12...24 0.2 - 0.4% DC - 150 Panel C/L LF Traction
300 - 400 +/-15 0.7 - 1 % DC - 50 Panel C/L LAC 300-S
350 - 500 +/- 15...+/- 24 0.5 - 0.6% DC - 100 Panel C/L LTC 350 - 500
250 - 4400 +/- 15..60
...+24
0.2 - 0.8% DC - 150 Panel C/L LT Traction
500 -1000 +/- 15... +/- 24 0.4 - 0.7% DC - 100 Panel C/L LTC 600 - 1000
500 - 3000 +/- 15 2.8% DC - 10 Panel O/L HTC
1000 +/- 15 1.2% DC - 10 Panel O/L HAR
4000 - 20000 +/- 15 1% DC - 3 Panel O/L HAZ
4000 +/-24 0.05% DC-80 Panel Fluxgate ITC series
             
<20 A AC on
<3000 A DC
+/- 15 <5 % 10 - 3000Hz Panel Rogowski RA Interference Current Measurement
             
+/- 2 +/- 15 2.5 % 5 Panel Fluxgate C CD Differential Current Measurement


Data is for general information only, Please refer to specific data sheet for each product.


Current measurement in trackside railway applications

Nominal Current Range Ipn (A) Power Supply Range (V) Global Accuracy @ +25°C, % of Ipn Bandwidth (kHz) Mounting Technology Series
10 - 30 0...+24 1 DC...1 Panel / Rail
DN
C/L Points Conditions Monitoring (PCM)


 

Shunt isolator to be used with shunt - in traction on-board and substations applications

Nominal Voltage Range Vpn Power Supply Range (V) Global Accuracy @ +25°C, % of Vpn Bandwidth (kHz) Mounting Technology Series
30 - 200 mV +/-13.5 ...26.4 0.3 10 Panel Insulating digital DI



Voltage measurement in traction on-board applications

With built-in resistor R1
Nominal Voltage Range Vpn Power Supply Range (V) Global Accuracy @ +25°C, % of Vpn Bandwidth (kHz) Mounting Technology Series
50 -2000 +/- 12...24 0.7 <13 Panel Isolation Amplifier AV 100-Voltage
50 - 2000 +/- 15...24 0.7 - 1.2 <10 Panel C/L LV 100-Voltage 1
85 - 1400 +/- 15...24 <0.375 <300 - 800 Panel Fluxgate C CV 3-Voltage
200 - 1200 +/- 12...15 0.8 - 0.9 <10 Panel C/L LV 25-Voltage
200 - 6400 +/- 15...24 0.8 - 2.5 <1 Panel C/L LV 200-AW/2/Voltage
2121 - 4242 +/- 15 & +/- 24 <1.4 <21 Panel Fluxgate C CV 4-Voltage
2500 - 4000 +/- 15...24 0.2 - 0.8 <10 Panel C/L LV 100-Voltage 2
1200 - 4200 +/- 13,5...26,4 0.4 <12 Panel Insulating digital DV Voltage


Without resistor R1
Nominal Voltage Range Ipn (Vpn) Power Supply Range (V) Global Accuracy @ +25°C, % of Ipn Bandwidth (kHz) Mounting Technology Series
10 mA
(10 - 500V)
+/- 12...15 0.8 - 1 <10 PCB C/L LV 25-P
10 - 210 mA
(100 - 2500V)
+/- 12...24 0.7 <10 Panel C/L LV 100
20 mA
(100 - 2500V)
+/- 15...24 0.6 <6 Panel C/L LV 200-AW/2