For Traction & Trackside
| Nominal Current Range Ipn (Apn) | Power Supply Range (V) | Global Accuracy @ +25°C, % of Ipn | Bandwidth (kHz) | Mounting | Technology | Series |
| 0.25 - 200 | +/- 12...15 | 0.4 - 0.9% | DC - 150 | PCB | C/L | LA 25-200 -P |
| 100 - 1000 | +/- 15 | 1 - 1.35% | DC - 50 | Panel | O/L | HTA Traction |
| 200- 500 | +/- 12...24 | 0.6 - 0.9% | DC - 100 | Panel | C/L | LA 205 / 305 -S/ -T Traction |
| 200 - 500 | +/- 24 | 1% | DC - 100 | Split core | C/L | LA 200 / 500-SD |
| 200 - 2000 | +/- 12...24 | 0.2 - 0.4% | DC - 150 | Panel | C/L | LF Traction |
| 300 - 400 | +/-15 | 0.7 - 1 % | DC - 50 | Panel | C/L | LAC 300-S |
| 350 - 500 | +/- 15...+/- 24 | 0.5 - 0.6% | DC - 100 | Panel | C/L | LTC 350 - 500 |
| 250 - 4400 | +/- 15..60 ...+24 |
0.2 - 0.8% | DC - 150 | Panel | C/L | LT Traction |
| 500 -1000 | +/- 15... +/- 24 | 0.4 - 0.7% | DC - 100 | Panel | C/L | LTC 600 - 1000 |
| 500 - 3000 | +/- 15 | 2.8% | DC - 10 | Panel | O/L | HTC |
| 1000 | +/- 15 | 1.2% | DC - 10 | Panel | O/L | HAR |
| 4000 - 20000 | +/- 15 | 1% | DC - 3 | Panel | O/L | HAZ |
| 4000 | +/-24 | 0.05% | DC-80 | Panel | Fluxgate | ITC series |
| <20 A AC on <3000 A DC |
+/- 15 | <5 % | 10 - 3000Hz | Panel | Rogowski | RA Interference Current Measurement |
| +/- 2 | +/- 15 | 2.5 % | 5 | Panel | Fluxgate C | CD Differential Current Measurement |
Data is for general information only, Please refer to specific data sheet for each product.
Current measurement in trackside railway applications
| Nominal Current Range Ipn (A) | Power Supply Range (V) | Global Accuracy @ +25°C, % of Ipn | Bandwidth (kHz) | Mounting | Technology | Series |
| 10 - 30 | 0...+24 | 1 | DC...1 | Panel / Rail DN |
C/L | Points Conditions Monitoring (PCM) |
Shunt isolator to be used with shunt - in traction on-board and substations applications
| Nominal Voltage Range Vpn | Power Supply Range (V) | Global Accuracy @ +25°C, % of Vpn | Bandwidth (kHz) | Mounting | Technology | Series |
| 30 - 200 mV | +/-13.5 ...26.4 | 0.3 | 10 | Panel | Insulating digital | DI |
Voltage measurement in traction on-board applications
With built-in resistor R1| Nominal Voltage Range Vpn | Power Supply Range (V) | Global Accuracy @ +25°C, % of Vpn | Bandwidth (kHz) | Mounting | Technology | Series |
| 50 -2000 | +/- 12...24 | 0.7 | <13 | Panel | Isolation Amplifier | AV 100-Voltage |
| 50 - 2000 | +/- 15...24 | 0.7 - 1.2 | <10 | Panel | C/L | LV 100-Voltage 1 |
| 85 - 1400 | +/- 15...24 | <0.375 | <300 - 800 | Panel | Fluxgate C | CV 3-Voltage |
| 200 - 1200 | +/- 12...15 | 0.8 - 0.9 | <10 | Panel | C/L | LV 25-Voltage |
| 200 - 6400 | +/- 15...24 | 0.8 - 2.5 | <1 | Panel | C/L | LV 200-AW/2/Voltage |
| 2121 - 4242 | +/- 15 & +/- 24 | <1.4 | <21 | Panel | Fluxgate C | CV 4-Voltage |
| 2500 - 4000 | +/- 15...24 | 0.2 - 0.8 | <10 | Panel | C/L | LV 100-Voltage 2 |
| 1200 - 4200 | +/- 13,5...26,4 | 0.4 | <12 | Panel | Insulating digital | DV Voltage |
Without resistor R1
| Nominal Voltage Range Ipn (Vpn) | Power Supply Range (V) | Global Accuracy @ +25°C, % of Ipn | Bandwidth (kHz) | Mounting | Technology | Series |
| 10 mA (10 - 500V) |
+/- 12...15 | 0.8 - 1 | <10 | PCB | C/L | LV 25-P |
| 10 - 210 mA (100 - 2500V) |
+/- 12...24 | 0.7 | <10 | Panel | C/L | LV 100 |
| 20 mA (100 - 2500V) |
+/- 15...24 | 0.6 | <6 | Panel | C/L | LV 200-AW/2 |