CDSR Series

CDSR is a leakage current sensor developed to meet market demand for a residential and commercial charging station, offering a version for single-phase architecture and another for three-phase topology. With a maximum current per phase of 32A rms, the CDSR can be integrated into AC chargers from 3.7 kW to 22kW.
 

CDSR 0.07-TP / -NP

CDSR Series

MAIN CHARACTERISTICS:

  • RCD type B measuring levels
  • Fluxgate Open loop current sensor
  • Voltage and SPI digital output 
  • Single supply voltage 3.3 V
  • PCB mounting
  • Very low error at small currents measurement
  • High overload capability 
  • High insulation capability 
  • Test winding.

FEATURES:

  • Primary current 32 A RMS
  • 150 ± mA AC and DC measuring range
  • ±0.5 mA accuracy at 5 mA AC and DC
  • Dual output with digital com. (SPI) and Analog
  • Test winding
  • < 50 mA current consumption at 3.3V
  • -40°C to 85°C operating temperature
  • DC to 2kHz Bandwidth
  • 8 mm Creepage and Clearance distances Prim. / Sec.
  • PD2 OVC2 (TP) /OVC3 (NP) 300 V UL 840, 4000 m
  • Ratiometric and differential output signal
  • IEC 62752 / 62955 / 61851-1 / UL 2231-1,2

Typical applications

Download Press Release

CDSR Series - Download & Technical characteristics

Product Document Standard Max primary current (ARMS) Leakage Measuring Range (ADC) Bandwidth (Hz) Output
CDSR-NP

Datasheet
3D
ECAD Models

IEC 62955, IEC 62752, UL 2231, IEC 61851-1 32Arms per phase 3P+N ±150 mA AC & DC 2 kHz

SPI & Analog output

CDSR-TP

Datasheet
3D
ECAD Models

IEC 62955, IEC 62752, UL 2231, IEC 61851-1 32Arms per phase P+N ±150 mA AC & DC 2 kHz SPI & Analog output

CDSR Series - Ask for samples / quotation

Looking to receive samples or a quotation? Please click on the contact button below and provide us with the information you need on this product series. Our sales team will get back to you shortly.

Contact Us