PCM

PCM, Points Condition Monitoring. Closed loop Hall effect based current transducers to monitor the points in trackside applications. DC, AC pulse currents' measurements from 5 to 30 A DC or RMS nominal with galvanic isolation. Compact split core design to make the maintenance easy. To be panel mounted. Aperture 15.6 mm diameter for the primary conductor crossing. Current output. Single supply + 24 V.

型号细节

PCM 30-P

30 ADC nominal, -25°C to +55°C, IP 67, 4-20 mA current output (4 mA for -Ip, 12 mA for 0 A, 20 mA for +Ip), Secondary connections on Switchcraft connector.

系列
PCM
测量类型
电流
额定值
30 A
测量范围
60 A
副边输出信号
电流
副边输出信号值
瞬时 4-20mA
原边信号
AC + DC
工作电压
外部供电 DC 单向
工作电压范围
24 - 24 V
精度
1 %
工作温度
-25 °C / 55 °C
技术
闭环霍尔效应
安装
盘式
应用
轨旁
PCM 30-P
PICTURE
FRONT
BACK
LEFT
RIGHT
下载

相关信息

订单

联系方式

系列

同系列产品

PCM 30-P/SP2

30 ADC nominal, -25°C to +55°C, 4-20 mA current output (4 mA for -Ip, 12 mA for 0 A, 20 mA for +Ip), Secondary connections on 3 m cable

PCM 5-PR/SP2

5 A AC RMS nominal, -25°C to +55°C, IP 67, 4-20 mA DC True RMS current output (4 mA for 0 A, 12 mA for Ipn, 20 mA for 2xIpn), Secondary connections on cable.

PCM 30-P/SP1

30 ADC nominal, -25°C to +55°C, 4-20 mA current output (4 mA for 0 A, 20 mA for +Ip), Secondary connections on cable.

PCM 20-P

20 ADC nominal, -25°C to +55°C, IP 67, 4-20 mA current output (4 mA for -Ip, 12 mA for 0 A, 20 mA for +Ip), Secondary connections on Switchcraft connector.

PCM 10-P/SP1

10 ADC nominal, -25°C to +55°C, 4-20 mA current output (4 mA for -Ip, 12 mA for 0 A, 20 mA for +Ip), Secondary connections on cable.

PCM 10-P

10 ADC nominal, -40°C to +85°C, IP 67, 4-20 mA current output (4 mA for -Ip, 12 mA for 0 A, 20 mA for +Ip), Secondary connections on Switchcraft connector.