IT 1000-S/SP1 ULTRASTAB
High accurate current transducer for 707 ARMS nominal.
Made for high accuracy. DC, AC pulse currents' measurements from 700 to 1000 ADC nominal with galvanic isolation. Excellent linearity, better than 3 ppm. High resolution. Initial offset between 50 to 60 ppm. Very low offset drift: between 0.5 to 4 ppm/K. Overall accuracy @ Ipn @ +25°C: between < +/- 0.0059% and < +/- 0.015%. ,Wide frequency bandwidth up to 500 kHz (+/- 3 dB). Fluxgate technology. Electrostatic shield between primary and secondary circuit. Power supply +/-15 V. Operating temperature range from +10 to +50°C. D-Sub 9 male interface output. Current output. Really quick response time (<250 µs)
High accurate current transducer for 700 ARMS nominal. +/- 10 V output. Linearity error 30 ppm. Sensitivity error 50 ppm.