ITC4000

Class accuracy R (Railway) current measurement. DC, AC, pulse high accurate non-invasive measurements of currents up to 4000 ARMS with high galvanic isolation (isolation test voltage: 14 KVRMS / 50Hz / 1 min). Closed loop Fluxgate technology. Measuring range: up to 6000 ApK. Max overall accuracy: +/- 0.05 % of Ipn at +25°C. Class 0.5 R according to EN50463. Max overall accuracy (+23°C): +/- 0.2% of reading @ 10 % of Ipn, +/- 0.4% of reading @ 5 % of Ipn, +/- 2% of reading @ 1 % of Ipn. Power Supply: +/- 21.6 to +/- 26.4 V. Operating temperature range: -40 to +85°C. Analogue current output. Reduced size & low power losses. Really low current consumption. Current overload: 100kA/100ms. Fast response time: 0,1µs. Large bandwidth: up to 80 KHz (3dB). Low temperature drift of accuracy.

モデル詳細

ITC 4000-S

4000 ARMS nominal. Analogue current output: 1.6 A @ Ipn. Aperture of 102 mm diameter. Really low current consumption: 300 mA.

シリーズ
ITC4000
測定
電流センサ
公称値
4000 A
測定範囲
6000 A
二次公称信号
電流
二次公称信号値
瞬時 1600 mA
一次信号
AC + DC
電源電圧
外部DCバイポーラ
電源電圧範囲
24 - 24 V
精度
0.05 %
動作温度
-40 °C / 85 °C
技術
クローズドループ・フラックスゲート ITC タイプ
取り付け
パネル
アプリケーション
高精度
鉄道(車載)
ITC 4000-S
代理店からのご注文

在庫確認

シリーズ

同じシリーズの製品

ITC 4000-S/SP2

4000 ARMS nominal. Analogue current output: 1.6 A @ Ipn. Aperture of 102 mm diameter. Really low current consumption: 70 mA. Engraved serialnumber.

注文

連絡先