ITC4K
Class accuracy R (Railway) current measurement. DC, AC, pulse high accurate non-invasive measurements of currents up to 4000 ARMS with high galvanic isolation (isolation test voltage: 14 KVRMS / 50Hz / 1 min). Closed loop Fluxgate technology. Measuring range: up to 6000 ApK. Max overall accuracy: +/- 0.05 % of Ipn at +25°C. Class 0.5 R according to EN50463. Max overall accuracy (+23°C): +/- 0.2% of reading @ 10 % of Ipn, +/- 0.4% of reading @ 5 % of Ipn, +/- 2% of reading @ 1 % of Ipn. Power Supply: +/- 21.6 to +/- 26.4 V. Operating temperature range: -40 to +85°C. Analogue current output. Reduced size & low power losses. Really low current consumption. Current overload: 100kA/100ms. Fast response time: 0,1µs. Large bandwidth: up to 80 KHz (3dB). Low temperature drift of accuracy.
ITC 4000-S
4000 ARMS nominal. Analogue current output: 1.6 A @ Ipn. Aperture of 102 mm diameter. Really low current consumption: 300 mA.
- Series
-
ITC4K
- Measurement
-
電流センサ
- Nominal Value
-
4000 A
- Measuring Range
-
6000 A
- Second. Nominal Signal
-
電流
- Second. Nominal Signal Value
- 瞬時 1600 mA
- Primary Signal
-
AC + DC
- Supply Voltage
-
外部DCバイポーラ
- Supply Voltage Range
- 24 - 24 V
- Accuracy
- 0.05 %
- Op. Temperature
- -40 °C / 85 °C
- 技術
-
クローズドループ・フラックスゲート ITC タイプ
- Mounting
-
パネル
- アプリケーション
-
高精度鉄道(車載)