LF306
Closed Loop Hall effect. DC, AC pulse currents' measurements of 300 ARMS nominal with galvanic isolation. Compact and ultra flat design. To be panel mounted in various ways. Aperture 25.5 x 25.5 mm for the primary conductor crossing. Excellent accuracy, good response time, Current output, -25°C to + 70°C. Dual supply +/- 12 to +/- 15 V.
Model details
LF 306-S/SP10
300 ARMS nominal. Secondary connections to be soldered on PCB
- Series
-
LF306
- Measurement
-
電流センサ
- Nominal Value
-
300 A
- Measuring Range
-
500 A
- Second. Nominal Signal
-
電流
- Second. Nominal Signal Value
- 瞬時 150 mA
- Primary Signal
-
AC + DC
- Supply Voltage
-
外部DCバイポーラ
- Supply Voltage Range
- 12 - 15 V
- Accuracy
- 0.4 %
- Op. Temperature
- -25 °C / 70 °C
- 技術
-
クローズドループ・ホール効果
- Mounting
-
パネル基板
- アプリケーション
-
ドライブ電源再生可能エネルギー溶接

PICTURE
FRONT
BACK
LEFT
RIGHT
ダウンロード