HTB

DC, AC pulse currents' measurements from 50 A up to 400 ARMS with galvanic isolation. 7 models with a unique size to be mounted on PCB on only 4,3 cm2 area (and 34 mm in height). Dual supply +/- 12 to 15 V. Voltage output.

Model details

HTB 100-P/SP5

100 ARMS nominal, Unipolar power supply 0 to +12...15 V=Uc, Voltage output: Uc/2 +/- 1.667 V at +/- Ipn.

Series
HTB
Measurement
Current
Nominal Value
100 A
Measuring Range
300 A
Second. Nominal Signal
Voltage
Second. Nominal Signal Value
Instantaneous Vc/2 +/- 1.667 V
Primary Signal
AC + DC
Supply Voltage
External DC Unipolar
Supply Voltage Range
12 - 15 V
Accuracy
1 %
Op. Temperature
-25 °C / 85 °C
Technology
Open loop Hall effect
Mounting
PCB
Applications
Drives
Power Supplies
Renewable Energies
Welding
HTB 100-P/SP5
PICTURE
FRONT
BACK
LEFT
RIGHT
Download

Relative information

Order

Contact Information

Series

Product of the same series

HTB 50-TP

50 ARMS nominal, 4 V output at Ipn, Integrating the jumper primary conductor.

HTB 50-P/SP5

50 ARMS nominal, Unipolar power supply 0 to +12...15 V=Uc, Voltage output: Uc/2 +/- 1.667 V at +/- Ipn

HTB 50-P

50 ARMS nominal, 4 V output at Ipn, 16 mm diameter for the aperture for the primary conductor.

HTB 400-P/SP5

400 ARMS nominal, Unipolar power supply 0 to +12...15 V=Uc, Voltage output: Uc/2 +/- 1.667 V at +/- Ipn.

HTB 400-P

400 ARMS nominal, 4 V output at Ipn, 16 mm diameter for the aperture for the primary conductor.

HTB 300-P/SP5

300 ARMS nominal, Unipolar power supply 0 to +12...15 V=Uc, Voltage output: Uc/2 +/- 1.667 V at +/- Ipn.

HTB 300-P

300 ARMS nominal, 4 V output at Ipn, 16 mm diameter for the aperture for the primary conductor.

HTB 200-P

200 ARMS nominal, 4 V output at Ipn, 16 mm diameter for the aperture for the primary conductor.

HTB 150-P

200 ARMS nominal, 4 V output at Ipn, 16 mm diameter for the aperture for the primary conductor.

HTB 100-TP

100 ARMS nominal, 4 V output at Ipn, Integrating the jumper primary conductor.

HTB 100-P

100 ARMS nominal, 4 V output at Ipn, 16 mm diameter for the aperture for the primary conductor.