LA130150

Closed Loop Hall effect. DC, AC pulse currents' measurements of 130...150 ARMS nominal with galvanic isolation.To be PCB mounted. Aperture 13.5 x 10 mm for the primary conductor crossing. Excellent accuracy, good response time, -40°C to + 85°C.

Model details

LA 150-TP/SP1

150 ARMS nominal. Special busbar, Basic insulation voltage: 1500 V

Series
LA130150
Measurement
Current
Nominal Value
150 A
Measuring Range
212 A
Second. Nominal Signal
Current
Second. Nominal Signal Value
Instantaneous 75 mA
Primary Signal
AC + DC
Supply Voltage
External DC Bipolar
Supply Voltage Range
12 - 15 V
Accuracy
0.5 %
Op. Temperature
-40 °C / 85 °C
Technology
Closed loop Hall effect
Mounting
PCB
Applications
Drives
Power Supplies
Renewable Energies
Welding
LA 150-TP/SP1
PICTURE
FRONT
BACK
LEFT
RIGHT
Download

Relative information

Order

Contact Information

Series

Product of the same series

LA 150-TP

150 ARMS nominal. Integrating the primary conductor.