LA25NP

Closed Loop Hall effect. DC, AC pulse currents' measurements of 5, 6, 8, 12 & 25 ARMS nominal with galvanic isolation. Multi-range. To be PCB mounted (Primary and secondary). Integrated primary conductor. Excellent accuracy, good response time, -40°C to + 85°C.

Model details

LA 25-NP/SP34

1.5 ARMS nominal, Not multi-range, Turns ratio 16/1000, -40°C to +85°C

Series
LA25NP
Measurement
Current
Nominal Value
1.5 A
Measuring Range
2.2 A
Second. Nominal Signal
Current
Second. Nominal Signal Value
Instantaneous 24 mA
Primary Signal
AC + DC
Supply Voltage
External DC Bipolar
Supply Voltage Range
15 - 15 V
Accuracy
0.6 %
Op. Temperature
-40 °C / 85 °C
Technology
Closed loop Hall effect
Mounting
PCB
Applications
Trackside
Traction
LA 25-NP/SP34
PICTURE
FRONT
BACK
LEFT
RIGHT
Download

Relative information

Order

Contact Information

Series

Product of the same series

LA 25-NP/SP9

1.5 ARMS nominal, Not multi-range, Turns ratio 16/1000, 0...+70°C

LA 25-NP/SP8

2 ARMS nominal, Not multi-range, Turns ratio 12/1000, 0...+70°C

LA 25-NP/SP7

2.5 ARMS nominal, Not multi-range, Turns ratio 10/1000, 0...+70°C.

LA 25-NP/SP25

Multirange 5,6, 8, 12 and 25 A nominal according to PCB design, -40°C to +85°C, 2.5 kVRMS as test isolation voltage (4 kVDC/5mn)

LA 25-NP/SP14

0.25 ARMS nominal, Not multi-range, Turns ratio 100/1000, -10°C to +70°C.

LA 25-NP/SP13

0.5 ARMS nominal, Not multi-range, Turns ratio 50/1000, -40°C to +70°C.

LA 25-NP

Multirange 5,6, 8, 12 and 25 ARMS nominal according to PCB design