Coreless Field sensor, 20A, 2% Accuracy, 5V Power supply, Over Current Detection
6 selectable sensitivities depending on Rogowski coil: 22.5, 70, 80, 85, 100, 120 mV/kA at 50 Hz and delivering 1 A instantaneous output signals for 12 selectable In ranges: 100, 200, 300, 400, 500, 600, 800, 1000, 1500, 2000, 4000, 5000 A
10 ARMS nominal
3 ARMS nominal. Dual power supply: +/- 12...15 V
5 ARMS nominal. Dual power supply: +/- 12...15 V
10 ARMS nominal. Dual power supply: +/- 12...15 V
15 ARMS nominal. Dual power supply: +/- 12...15 V
20 ARMS nominal. Dual power supply: +/- 12...15 V
25 ARMS nominal. Dual power supply: +/- 12...15 V
50 ARMS nominal. Dual power supply: +/- 12...15 V
5 ARMS nominal. Dual power supply: +/- 12...15 V
10 ARMS nominal. Dual power supply: +/- 12...15 V
20 ARMS nominal. Dual power supply: +/- 12...15 V
25 ARMS nominal. Dual power supply: +/- 12...15 V
50 ARMS nominal. Dual power supply: +/- 12...15 V
100 ARMS nominal, 4 V output at Ipn, 16 mm diameter for the aperture for the primary conductor.
100 ARMS nominal, 4 V output at Ipn, Integrating the jumper primary conductor.
200 ARMS nominal, 4 V output at Ipn, 16 mm diameter for the aperture for the primary conductor.
200 ARMS nominal, 4 V output at Ipn, 16 mm diameter for the aperture for the primary conductor.
300 ARMS nominal, 4 V output at Ipn, 16 mm diameter for the aperture for the primary conductor.
400 ARMS nominal, 4 V output at Ipn, 16 mm diameter for the aperture for the primary conductor.
50 ARMS nominal, 4 V output at Ipn, 16 mm diameter for the aperture for the primary conductor.
50 ARMS nominal, Unipolar power supply 0 to +12...15 V=Uc, Voltage output: Uc/2 +/- 1.667 V at +/- Ipn
50 ARMS nominal, 4 V output at Ipn, Integrating the jumper primary conductor.
3 ARMS nominal. Single power supply: +12...15 V, Voltage output: +/-0.625+2.5V @ +/- Ipn.
Dual power supply +/- 12...15 V, Model with 2 integrated primary conductors to be connected either in series for 5 ARMS nominal measurement or in parallel for 10 ARMS nominal measurement.
5 ARMS nominal. Single power supply: +12...15 V, Voltage output: +/-0.625+2.5V @ +/- Ipn.
Dual power supply +/- 12...15 V, Model with 2 integrated primary conductors to be connected either in series for 10 ARMS nominal measurement or in parallel for 20 ARMS nominal measurement.
10 ARMS nominal. Single power supply: +12...15 V, Voltage output: +/-0.625+2.5V @ +/- Ipn.
50 ARMS nominal. Single power supply: +12...15 V, Voltage output: +/-0.625+2.5V @ +/- Ipn.
15 ARMS nominal
25 ARMS nominal
5 ARMS nominal
50 ARMS nominal. Power supply +/- 15 Volt
DC Current range 50, 75 & 100A selectable by a jumper, Unipolar voltage output: 0-10 V DC @ +/- Ipn, Split core
DC Current range 50, 75 & 100A selectable by a jumper, Unipolar current output: 4-20 mA DC @ +/- Ipn, Split core
DC Current range 50, 75 & 100A selectable by a jumper, Unipolar voltage output: 0-5 V DC @ +/- Ipn, Split core
Unipolar DC Current range 50, 75 & 100A selectable by a jumper, Unipolar voltage output: 0-10 V DC @ + Ipn (0V @ -Ipn and @ 0 A), Solid core
Bipolar DC Current range 50, 75 & 100A selectable by a jumper, Current output: 4-20 mA DC @ + Ipn (4 mA @ -Ipn and 12 mA @ 0 A), Solid core
Unipolar DC Current range 50, 75 & 100A selectable by a jumper, Unipolar current output: 4-20 mA DC @ + Ipn (0 mA @ -Ipn and 4 mA @ 0 A), Solid core