ART

Unique, IPx7, thin, light, flexible, split-core AC Rogowski Coil current sensor from 10 to 10000 ARMS with Class accuracy 0.5 according to IEC 61869 regardless of primary conductor position and rated insulation voltage 1kV CATIII.

Model details

ART-B22-D300/SP4

ART are calibrated & provided with a Class accuracy 0.5. ART needs an integrator at its output. Output voltage: 22.5 mV/kA. 300 mm aperture. Output cable length: 4.5m

Series
ART
Measurement
Ток
Nominal Value
1000 A
Measuring Range
A
Second. Nominal Signal
Напряжение
Second. Nominal Signal Value
Мгновенное значение V
Primary Signal
Переменный ток
Supply Voltage
Не требует внешнего питания
Accuracy
0.5 %
Op. Temperature
-40 °C / 80 °C
Технология
С катушкой Роговского
Mounting
На первичную шину
Применения
Smart Grid
ART-B22-D300/SP4
PICTURE
FRONT
BACK
LEFT
RIGHT
Заказ

Контактная информация

Серии

Изделия этой серии

ART-B22-D125/SP25 3m, SMA

ART are calibrated & provided with a Class accuracy 0.5. ART needs an integrator at its output. Output voltage: 22.5 mV/kA. 125 mm aperture. 3 m output cable with SMA crimp plug.

ART-B22-D125

ART are calibrated & provided with a Class accuracy 0.5. ART needs an integrator at its output. Output voltage: 22.5 mV/kA. 125 mm aperture.

ART-B22-D175

ART are calibrated & provided with a Class accuracy 0.5. ART needs an integrator at its output. Output voltage: 22.5 mV/kA. 175 mm aperture.

ART-B22-D70

ART are calibrated & provided with a Class accuracy 0.5. ART needs an integrator at its output. Output voltage: 22.5 mV/kA. 70 mm aperture.

ART-B22-D125/SP4

ART are calibrated & provided with a Class accuracy 0.5. ART needs an integrator at its output. Output voltage: 22.5 mV/kA. 125 mm aperture. Output cable length: 4.5m

ART-B22-D125/SP6

ART are calibrated & provided with a Class accuracy 0.5. ART needs an integrator at its output. Output voltage: 22.5 mV/kA. 125 mm aperture. Output cable length:6m

ART-B22-D175/SP3

ART are calibrated & provided with a Class accuracy 0.5. ART needs an integrator at its output. Output voltage: 22.5 mV/kA. 175 mm aperture. Output cable length: 3m

ART-B22-D300

ART are calibrated & provided with a Class accuracy 0.5. ART needs an integrator at its output. Output voltage: 22.5 mV/kA. 300 mm aperture.

ART-B22-D70/SP3

ART are calibrated & provided with a Class accuracy 0.5. ART needs an integrator at its output. Output voltage: 22.5 mV/kA. 70 mm aperture. Output cable length: 3m

ART-B22-D70/SP6

ART are calibrated & provided with a Class accuracy 0.5. ART needs an integrator at its output. Output voltage: 22.5 mV/kA. 70 mm aperture. Output cable length: 6m