LV100xx

Closed Loop Hall effect technology. DC, AC pulse voltage' measurements of 100 to 4000 VRMS nominal with galvanic isolation.To be panel mounted.

Model details

LV 100-5000/SP1

5000 VRMS nominal. +/- 15 to 24V +/- 10% power supply, -45°C to +85°C, Isolation test voltage 12kVRMS/50 Hz/1 min, Primary and secondary connections on M5 threaded studs, Shield, For traction.

Series
LV100xx
Measurement
Voltage
Nominal Value
5000 V
Measuring Range
8000 V
Second. Nominal Signal
Current
Second. Nominal Signal Value
Instantaneous 50 mA
Primary Signal
AC + DC
Supply Voltage
External DC Bipolar
Supply Voltage Range
15 - 24 V
Accuracy
1 %
Op. Temperature
-45 °C / 85 °C
Technology
Closed loop Hall effect
Mounting
Panel
Applications
Traction
PICTURE
FRONT
BACK
LEFT
RIGHT
Download

Relative information

Order

Contact Information

Select any filter and click on Apply to see results
Series

Product of the same series

LV 100-1000/SP13

1000 VRMS nominal. +/- 16 to 33 V power supply, 12 kVRMS as isolation test voltage, -25°C to +70°C, For traction.

LV 100-1000/SP16

1000 VRMS nominal. +/- 15 to +/- 24 V power supply, -25°C to +70°C, Secondary connections on M5 threaded studs, For traction.

LV 100-1000/SP9

1000 VRMS nominal. +/- 15 to +/- 24 V power supply, -40°C to +70°C, Primary and secondary connections on M5 threaded studs, For traction.

LV 100-1500/SP3

1500 VRMS nominal. +/- 15 to +/- 24 V power supply, -40°C to +85°C, Secondary connection on M5 threaded studs, For traction.

LV 100-2000/SP15

2000 VRMS nominal. +/- 15 to +/- 24 V power supply, 9 kVRMS isolation test voltage, -40°C to +75°C, Secondary connections on M5 threaded studs, Shield, For traction.