TRADING

DC, AC pulse currents' measurements from 50 A up to 400 ARMS with galvanic isolation. 7 models with a unique size to be mounted on PCB on only 4,3 cm2 area (and 34 mm in height). Dual supply +/- 12 to 15 V. Voltage output.

Model details

HTB 50-P/SP5

50 ARMS nominal, Unipolar power supply 0 to +12...15 V=Uc, Voltage output: Uc/2 +/- 1.667 V at +/- Ipn

Series
TRADING
Measurement
Current
Nominal Value
50 A
Measuring Range
150 A
Second. Nominal Signal
Voltage
Second. Nominal Signal Value
Instantaneous Vc/2 +/- 1.667 V
Primary Signal
AC + DC
Supply Voltage
External DC Unipolar
Supply Voltage Range
12 - 15 V
Accuracy
1 %
Op. Temperature
-25 °C / 85 °C
Technology
Open loop Hall effect
Mounting
PCB
Applications
Drives
Power Supplies
Renewable Energies
Welding
HTB 50-P/SP5
PICTURE
FRONT
BACK
LEFT
RIGHT
Download

Relative information

Order from our distributors

Check Stock

Series

Product of the same series

FHS AH 600

Coreless Field sensor, 20A, 2% Accuracy, 5V Power supply, Over Current Detection

AI-P1A

6 selectable sensitivities depending on Rogowski coil: 22.5, 70, 80, 85, 100, 120 mV/kA at 50 Hz and delivering 1 A instantaneous output signals for 12 selectable In ranges: 100, 200, 300, 400, 500, 600, 800, 1000, 1500, 2000, 4000, 5000 A

HX 03-P

3 ARMS nominal. Dual power supply: +/- 12...15 V

HX 05-P

5 ARMS nominal. Dual power supply: +/- 12...15 V

HX 10-P

10 ARMS nominal. Dual power supply: +/- 12...15 V

HX 15-P

15 ARMS nominal. Dual power supply: +/- 12...15 V

HX 20-P

20 ARMS nominal. Dual power supply: +/- 12...15 V

HX 25-P

25 ARMS nominal. Dual power supply: +/- 12...15 V

HX 50-P

50 ARMS nominal. Dual power supply: +/- 12...15 V

HXN 05-P

5 ARMS nominal. Dual power supply: +/- 12...15 V

HXN 10-P

10 ARMS nominal. Dual power supply: +/- 12...15 V

HXN 20-P

20 ARMS nominal. Dual power supply: +/- 12...15 V

HXN 25-P

25 ARMS nominal. Dual power supply: +/- 12...15 V

HXN 50-P

50 ARMS nominal. Dual power supply: +/- 12...15 V

HTB 100-P

100 ARMS nominal, 4 V output at Ipn, 16 mm diameter for the aperture for the primary conductor.

HTB 100-TP

100 ARMS nominal, 4 V output at Ipn, Integrating the jumper primary conductor.

HTB 150-P

200 ARMS nominal, 4 V output at Ipn, 16 mm diameter for the aperture for the primary conductor.

HTB 200-P

200 ARMS nominal, 4 V output at Ipn, 16 mm diameter for the aperture for the primary conductor.

HTB 300-P

300 ARMS nominal, 4 V output at Ipn, 16 mm diameter for the aperture for the primary conductor.

HTB 400-P

400 ARMS nominal, 4 V output at Ipn, 16 mm diameter for the aperture for the primary conductor.

HTB 50-P

50 ARMS nominal, 4 V output at Ipn, 16 mm diameter for the aperture for the primary conductor.

HTB 50-TP

50 ARMS nominal, 4 V output at Ipn, Integrating the jumper primary conductor.

HX 03-P/SP2

3 ARMS nominal. Single power supply: +12...15 V, Voltage output: +/-0.625+2.5V @ +/- Ipn.

HX 05-NP

Dual power supply +/- 12...15 V, Model with 2 integrated primary conductors to be connected either in series for 5 ARMS nominal measurement or in parallel for 10 ARMS nominal measurement.

HX 05-P/SP2

5 ARMS nominal. Single power supply: +12...15 V, Voltage output: +/-0.625+2.5V @ +/- Ipn.

HX 10-NP

Dual power supply +/- 12...15 V, Model with 2 integrated primary conductors to be connected either in series for 10 ARMS nominal measurement or in parallel for 20 ARMS nominal measurement.

HX 10-P/SP2

10 ARMS nominal. Single power supply: +12...15 V, Voltage output: +/-0.625+2.5V @ +/- Ipn.

HX 50-P/SP2

50 ARMS nominal. Single power supply: +12...15 V, Voltage output: +/-0.625+2.5V @ +/- Ipn.

HY 50-P

50 ARMS nominal. Power supply +/- 15 Volt

DK 100 B10

DC Current range 50, 75 & 100A selectable by a jumper, Unipolar voltage output: 0-10 V DC @ +/- Ipn, Split core

DK 100 B420

DC Current range 50, 75 & 100A selectable by a jumper, Unipolar current output: 4-20 mA DC @ +/- Ipn, Split core

DK 100 B5

DC Current range 50, 75 & 100A selectable by a jumper, Unipolar voltage output: 0-5 V DC @ +/- Ipn, Split core

DK 100 C10 U

Unipolar DC Current range 50, 75 & 100A selectable by a jumper, Unipolar voltage output: 0-10 V DC @ + Ipn (0V @ -Ipn and @ 0 A), Solid core

DK 100 C420 B

Bipolar DC Current range 50, 75 & 100A selectable by a jumper, Current output: 4-20 mA DC @ + Ipn (4 mA @ -Ipn and 12 mA @ 0 A), Solid core

DK 100 C420 U

Unipolar DC Current range 50, 75 & 100A selectable by a jumper, Unipolar current output: 4-20 mA DC @ + Ipn (0 mA @ -Ipn and 4 mA @ 0 A), Solid core

DK 20 C10 U

Unipolar DC Current range 5, 10 & 20A selectable by a jumper, Unipolar voltage output: 0-10 V DC @ + Ipn (0 V @ -Ipn and @ 0 A), Solid core

Order

Contact Information