HTB
DC, AC pulse currents' measurements from 50 A up to 400 ARMS with galvanic isolation. 7 models with a unique size to be mounted on PCB on only 4,3 cm2 area (and 34 mm in height). Dual supply +/- 12 to 15 V. Voltage output.
Model details
HTB 50-P
50 ARMS nominal, 4 V output at Ipn, 16 mm diameter for the aperture for the primary conductor.
- Series
-
HTB
- Measurement
-
Current
- Nominal Value
-
50 A
- Measuring Range
-
150 A
- Second. Nominal Signal
-
Voltage
- Second. Nominal Signal Value
- Instantaneous 4 V
- Primary Signal
-
AC + DC
- Supply Voltage
-
External DC Bipolar
- Supply Voltage Range
- 12 - 15 V
- Accuracy
- 1 %
- Op. Temperature
- -40 °C / 80 °C
- Technology
-
Open loop Hall effect
- Mounting
-
PCB
- Applications
-
DrivesPower SuppliesRenewable EnergiesWelding

PICTURE
FRONT
BACK
LEFT
RIGHT
Download