Информация о компании
LF210-S
Closed Loop ASIC based Hall effect. DC, AC pulse currents' measurements of 200 ARMS nominal with galvanic isolation. Compact design. To be panel mounted in various ways. Aperture 15.59 mm diameter for the primary conductor crossing. Excellent high accuracy at the level of Fluxgate technology but at the price of Hall effect. Overall accuracy over temperature range of 0.2 % of Ipn, Exceptional offset drift of 0.1 % of Ipn. Fast response time less than 0.5 µs, Current output, -40°C to + 85°C. Dual supply +/- 12 to +/- 15V.
Model details
LF 210-S
High mounting versatility, high accuracy over operating temperature range, 200 ARMS nominal.
- Series
-
LF210-S
- Measurement
-
Ток
- Nominal Value
-
200 A
- Measuring Range
-
420 A
- Second. Nominal Signal
-
Ток
- Second. Nominal Signal Value
- Мгновенное значение 100 mA
- Primary Signal
-
Переменный + постоянный ток
- Supply Voltage
-
Внешнее двухполярное постоянного тока
- Supply Voltage Range
- 12 - 15 V
- Accuracy
- 0.2 %
- Op. Temperature
- -40 °C / 85 °C
- Технология
-
Компенсационные на основе эффекта Холла
- Mounting
-
На панель
- Применения
-
ПриводыСистемы электропитанияВозобновляемые источники энергииСварка

PICTURE
FRONT
BACK
LEFT
RIGHT
Скачать