Contact Us Contact Us

HXN

DC, AC and pulse small currents' measurements from 3 to 50ARMS nominal with galvanic isolation. Small size and compact design at low prices. Only 2.93 cm2 as PCB mounting area are needed to support the 8g of these transducers. 8 models. PCB mounting. Measuring range up to 3 x Ipn. Dual supply +/- 12 to +/- 15V. Voltage output

Model details

HXN 10-P

10 ARMS nominal. Dual power supply: +/- 12...15 V

Series
HXN
Measurement
Current
Nominal Value
10 A
Measuring Range
30 A
Second. Nominal Signal
Voltage
Second. Nominal Signal Value
Instantaneous 4 V
Primary Signal
AC + DC
Supply Voltage
External DC Bipolar
Supply Voltage Range
15 - 15 V
Accuracy
1 %
Op. Temperature
-25 °C / 85 °C
Technology
Open loop Hall effect
Mounting
PCB
Applications
Drives
Power Supplies
Renewable Energies
Welding