LF505S
Closed Loop Hall effect. DC, AC pulse currents' measurements of 500 ARMS nominal with galvanic isolation. Compact design. To be panel mounted in various ways. Aperture 30.2 mm diameter for the primary conductor crossing. Excellent accuracy, good response time, Current output, -40°C to + 70°C. Dual supply +/- 15 to +/- 24V.
Model details
LF 505-S/SP22
High mounting versatility, 500 ARMS nominal. Turns ratio 1/3500, Output on M4 threaded studs, For Traction
- Series
-
LF505S
- Measurement
-
Current
- Nominal Value
-
500 A
- Measuring Range
-
1200 A
- Second. Nominal Signal
-
Current
- Second. Nominal Signal Value
- Instantaneous 143 mA
- Primary Signal
-
AC + DC
- Supply Voltage
-
External DC Bipolar
- Supply Voltage Range
- 15 - 24 V
- Accuracy
- 0.6 %
- Op. Temperature
- -40 °C / 70 °C
- Technology
-
Closed loop Hall effect
- Mounting
-
Panel
- Applications
-
Traction
PICTURE
FRONT
BACK
LEFT
RIGHT
Download