HX

DC, AC and pulse small currents' measurements from 3 to 50ARMS nominal with galvanic isolation. Small size and compact design at low prices. Only 2.93 cm2 as PCB mounting area are needed to support the 8g of these transducers. 17 models in 3 different versions. PCB mounting. Measuring range up to 3 x Ipn. Dual supply +/- 12 to +/- 15V and single supply + 12 to + 15V. Voltage output

Model details

HX 15-P/SP2

15 ARMS nominal. Single power supply: +12...15 V, Voltage output: +/-0.625+2.5V @ +/- Ipn.

Series
HX
Measurement
Current
Nominal Value
15 A
Measuring Range
45 A
Second. Nominal Signal
Voltage
Second. Nominal Signal Value
Instantaneous 2.5 +/- 0.625 V
Primary Signal
AC + DC
Supply Voltage
External DC Unipolar
Supply Voltage Range
12 - 15 V
Accuracy
1 %
Op. Temperature
-25 °C / 85 °C
Technology
Open loop Hall effect
Mounting
PCB
Applications
Drives
Power Supplies
Renewable Energies
Welding
HX 15-P/SP2
PICTURE
FRONT
BACK
LEFT
RIGHT
Download

Relative information

Order from our distributors

Check Stock

Series

Product of the same series

HX 02-P

2 ARMS nominal. Dual power supply: +/- 12...15 V

HX 06-P

6 ARMS nominal. Dual power supply: +/- 12...15 V

Order