HX
DC, AC and pulse small currents' measurements from 3 to 50ARMS nominal with galvanic isolation. Small size and compact design at low prices. Only 2.93 cm2 as PCB mounting area are needed to support the 8g of these transducers. 17 models in 3 different versions. PCB mounting. Measuring range up to 3 x Ipn. Dual supply +/- 12 to +/- 15V and single supply + 12 to + 15V. Voltage output
Model details
HX 15-P/SP2
15 ARMS nominal. Single power supply: +12...15 V, Voltage output: +/-0.625+2.5V @ +/- Ipn.
- Series
-
HX
- Measurement
-
Current
- Nominal Value
-
15 A
- Measuring Range
-
45 A
- Second. Nominal Signal
-
Voltage
- Second. Nominal Signal Value
- Instantaneous 2.5 +/- 0.625 V
- Primary Signal
-
AC + DC
- Supply Voltage
-
External DC Unipolar
- Supply Voltage Range
- 12 - 15 V
- Accuracy
- 1 %
- Op. Temperature
- -25 °C / 85 °C
- Technology
-
Open loop Hall effect
- Mounting
-
PCB
- Applications
-
DrivesPower SuppliesRenewable EnergiesWelding

PICTURE
FRONT
BACK
LEFT
RIGHT
Download