DV

Voltage transducers for Industrial and Traction - for medium and high voltage measurements from 1200 to 4200 VRMS with an unique compact design, excellent overall accuracy and high insulation voltage

Model details

DV 1000

Bipolar and insulated measurement up to 1000 V, +/- 50 mA current output, Input and output connections on cables, Footprint compatible with CV4 and LV 200-AW/2 series.

Series
DV
Measurement
Voltage
Nominal Value
1000 V
Measuring Range
1500 V
Second. Nominal Signal
Current
Second. Nominal Signal Value
Instantaneous 50 mA
Primary Signal
AC + DC
Supply Voltage
External DC Bipolar
Supply Voltage Range
15 - 24 V
Accuracy
0.3 %
Op. Temperature
-40 °C / 85 °C
Technology
Insulation Digital Technology
Mounting
Panel
Applications
Drives
Power Supplies
Renewable Energies
Traction
Welding
DV 1000
Order

Contact Information

Series

Product of the same series

DV 3000/SP1

3000 VRMS nominal, Bipolar and insulated measurement up to 4500 V, +/- 50 mA current output, Input on M5 studs on the side and output on M5 studs on the other side + safety nuts, Footprint compatible with CV4 and LV 200-AW/2 series.

DV 6400

6400 VRMS nominal, Bipolar and insulated measurement up to 9050 V, +/- 50 mA current output, Input on M5 studs on the top and output on M5 studs + Faston + safety nuts, Footprint compatible with CV4 and LV 200-AW/2 series.

DV 4200/SP8

Bipolar and insulated measurement up to 4200 V, +/- 50 mA current output, Input on M5 studs on the top and output on M5 studs + Faston + safety nuts, Footprint compatible with CV4 and LV 200-AW/2 series.

DV 1200/SP2

Bipolar and insulated measurement up to 1200 V, +/- 50 mA current output, Input on cables, Output connections on M5 and faston studs, Footprint compatible with CV4 and LV 200-AW/2 series.

DV 1500

Bipolar and insulated measurement up to 1500 V, +/- 50 mA current output, Input connections on cables, Output connections on M5 studs or Faston, Footprint compatible with CV4 and LV 200-AW/2 series.

DV 2000

Bipolar and insulated measurement up to 2000 V, +/- 50 mA current output, Input & output connections on cables, Footprint compatible with CV4 and LV 200-AW/2 series.

DV 2000/SP2

Bipolar and insulated measurement up to 2000 V, +/- 50 mA current output, Input & output connections on M5 studs, Footprint compatible with CV4 and LV 200-AW/2 series.

DV 2800/SP4

Bipolar and insulated measurement up to 2800 V, +/- 50 mA current output, Input and output connections on M5 studs, Footprint compatible with CV4 and LV 200-AW/2 series.

DV 4000/SP2

Bipolar and insulated measurement up to 4000 V, +/- 50 mA current output, Input on M5 studs on the top, Output connections on Burndy connector, Footprint compatible with CV4 and LV 200-AW/2 series.

DV 4000/SP3

Bipolar and insulated measurement up to 4000 V, +/- 50 mA current output, Input and output on M5 studs + safety nuts, Footprint compatible with CV4 and LV 200-AW/2 series.

DV 4200/SP3

Bipolar and insulated measurement up to 4200 V, +/- 50 mA current output, Input and output on cables, Footprint compatible with CV4 and LV 200-AW/2 series.

DV 4200/SP4

Bipolar and insulated measurement up to 4200 V, +/- 50 mA current output, Input and output on M5 studs + safety nuts, Footprint compatible with CV4 and LV 200-AW/2 series.