IT60-400
Made for high accuracy. DC, AC pulse currents' measurements from 60 to 400 ADC nominal with galvanic isolation. Excellent linearity, better than 3 ppm. High resolution. Initial offset between 40 to 250 ppm. Very low offset drift: between 1 to 2.5 ppm/K. Overall accuracy @ Ipn @ +25°C: between < +/- 0.0051% and < +/- 0.0285%. ,Wide frequency bandwidth up to 800 kHz (+/- 3 dB). Fluxgate technology. Electrostatic shield between primary and secondary circuit. Power supply +/-15 V. Operating temperature range from +10 to +50°C. D-Sub 9 male interface output. Current output. Really quick response time (<250 µs)
Model details
IT 200-S ULTRASTAB
High accurate current transducer for 200 ARMS nominal.
- Series
-
IT60-400
- Measurement
-
Current
- Nominal Value
-
200 A
- Measuring Range
-
200 A
- Second. Nominal Signal
-
Current
- Second. Nominal Signal Value
- Instantaneous 200 mA
- Primary Signal
-
AC + DC
- Supply Voltage
-
External DC Bipolar
- Supply Voltage Range
- 15 - 15 V
- Accuracy
- 0.0084 %
- Op. Temperature
- 10 °C / 50 °C
- Technology
-
Closed loop Fluxgate IT type
- Mounting
-
Panel
- Applications
-
High Precision

PICTURE
FRONT
BACK
LEFT
RIGHT
Download