LEM
United States

LEM USA Inc.

11665 West Bradley Road
Milwaukee, WI, 53224
Соединенные Штаты

Связаться с нами Связаться с нами

ART

Unique, IPx7, thin, light, flexible, split-core AC Rogowski Coil current sensor from 10 to 10000 ARMS with Class accuracy 0.5 according to IEC 61869 regardless of primary conductor position and rated insulation voltage 1kV CATIII.

Model details

ART-B22-D125/SP25 3m, SMA

ART are calibrated & provided with a Class accuracy 0.5. ART needs an integrator at its output. Output voltage: 22.5 mV/kA. 125 mm aperture. 3 m output cable with SMA crimp plug.

Series
ART
Measurement
Ток
Nominal Value
1000 A
Measuring Range
A
Second. Nominal Signal
Напряжение
Second. Nominal Signal Value
Мгновенное значение V
Primary Signal
Переменный ток
Supply Voltage
Не требует внешнего питания
Accuracy
0.5 %
Op. Temperature
-40 °C / 80 °C
Технология
С катушкой Роговского
Mounting
На первичную шину
Применения
Smart Grid
PICTURE
FRONT
BACK
LEFT
RIGHT
Download

Relative information

Заказ

Контактная информация

Select any filter and click on Apply to see results
Серии

Изделия этой серии

ART-B22-D125

ART are calibrated & provided with a Class accuracy 0.5. ART needs an integrator at its output. Output voltage: 22.5 mV/kA. 125 mm aperture.

ART-B22-D125/SP4

ART are calibrated & provided with a Class accuracy 0.5. ART needs an integrator at its output. Output voltage: 22.5 mV/kA. 125 mm aperture. Output cable length: 4.5m

ART-B22-D125/SP6

ART are calibrated & provided with a Class accuracy 0.5. ART needs an integrator at its output. Output voltage: 22.5 mV/kA. 125 mm aperture. Output cable length:6m

ART-B22-D175

ART are calibrated & provided with a Class accuracy 0.5. ART needs an integrator at its output. Output voltage: 22.5 mV/kA. 175 mm aperture.

ART-B22-D175/SP3

ART are calibrated & provided with a Class accuracy 0.5. ART needs an integrator at its output. Output voltage: 22.5 mV/kA. 175 mm aperture. Output cable length: 3m

ART-B22-D175/SP4

ART are calibrated & provided with a Class accuracy 0.5. ART needs an integrator at its output. Output voltage: 22.5 mV/kA. 175 mm aperture. Output cable length: 4.5m

ART-B22-D175/SP6

ART are calibrated & provided with a Class accuracy 0.5. ART needs an integrator at its output. Output voltage: 22.5 mV/kA. 175 mm aperture. Output cable length: 6m

ART-B22-D300

ART are calibrated & provided with a Class accuracy 0.5. ART needs an integrator at its output. Output voltage: 22.5 mV/kA. 300 mm aperture.

ART-B22-D300/SP3

ART are calibrated & provided with a Class accuracy 0.5. ART needs an integrator at its output. Output voltage: 22.5 mV/kA. 300 mm aperture. Output cable length: 3m

ART-B22-D300/SP4

ART are calibrated & provided with a Class accuracy 0.5. ART needs an integrator at its output. Output voltage: 22.5 mV/kA. 300 mm aperture. Output cable length: 4.5m

ART-B22-D300/SP6

ART are calibrated & provided with a Class accuracy 0.5. ART needs an integrator at its output. Output voltage: 22.5 mV/kA. 300 mm aperture. Output cable length: 6m

ART-B22-D70

ART are calibrated & provided with a Class accuracy 0.5. ART needs an integrator at its output. Output voltage: 22.5 mV/kA. 70 mm aperture.

ART-B22-D70/SP3

ART are calibrated & provided with a Class accuracy 0.5. ART needs an integrator at its output. Output voltage: 22.5 mV/kA. 70 mm aperture. Output cable length: 3m

ART-B22-D70/SP4

ART are calibrated & provided with a Class accuracy 0.5. ART needs an integrator at its output. Output voltage: 22.5 mV/kA. 70 mm aperture. Output cable length: 4.5m

ART-B22-D70/SP6

ART are calibrated & provided with a Class accuracy 0.5. ART needs an integrator at its output. Output voltage: 22.5 mV/kA. 70 mm aperture. Output cable length: 6m