| Model | Measurement | Nominal value | Accuracy | Supply voltage | Second. Nominal Signal | |
|---|---|---|---|---|---|---|
| IST 400-B ULTRASTAB 10V OUTPUT IST |
Power supply | External AC 100 to 240 |
Other | |||
| DCBM_N4D_6010C20_0000C00 DCBM |
Energy | 600 A | External DC Unipolar 12 to 48 |
Other Communication |
||
| DCBM_N4D_6000C20_0000C00 DCBM |
Energy | 600 A | External DC Unipolar 12 to 48 |
Other Communication |
||
| DCBM_N4D_4010C20_0000C00 DCBM |
Energy | 400 A | External DC Unipolar 12 to 48 |
Other Communication |
||
| DCBM_N4D_4000C20_0000C00 DCBM |
Energy | 400 A | External DC Unipolar 12 to 48 |
Other Communication |
||
| DCBM_N4D_4000C15_0000C00 DCBM |
Energy | 400 A | External DC Unipolar 12 to 48 |
Other Communication |
||
| DCBM_N3D_6010C35_0000C00 DCBM |
Energy | 600 A | External DC Unipolar 12 to 48 |
Other Communication |
||
| DCBM_N3D_6010C25_0000C00 DCBM |
Energy | 600 A | External DC Unipolar 12 to 48 |
Other Communication |
||
| DCBM_N3D_6010C20_0000C00 DCBM |
Energy | 600 A | External DC Unipolar 12 to 48 |
Other Communication |
||
| DCBM_N3D_6000C20_0000C00 DCBM |
Energy | 600 A | External DC Unipolar 12 to 48 |
Other Communication |
||
| DCBM_N3D_4010C20_0000C00 DCBM |
Energy | 400 A | External DC Unipolar 12 to 48 |
Other Communication |
||
| DCBM_N3D_4000C20_0000C00 DCBM |
Energy | 400 A | External DC Unipolar 12 to 48 |
Other Communication |
||
| DCBM_N2D_6010C20_0000C00 DCBM |
Energy | 600 A | External DC Unipolar 12 to 48 |
Other Communication |
||
| DCBM_N2D_6000C20_0000C00 DCBM |
Energy | 600 A | External DC Unipolar 12 to 48 |
Other Communication |
||
| DCBM_N2D_4010C20_0000C00 DCBM |
Energy | 400 A | External DC Unipolar 12 to 48 |
Other Communication |
||
| DCBM_N2D_4000C20_0000C00 DCBM |
Energy | 400 A | External DC Unipolar 12 to 48 |
Other Communication |
||
| DCBM_N1M_0810W00_0000C00 DCBM100 |
Energy | 80 A | External DC Unipolar 12 to 24 |
Other Communication |
||
| DCBM_N1M_0800W00_0000C00 DCBM100 |
Energy | 80 A | External DC Unipolar 12 to 24 |
Other Communication |
||
| DCBM_N1D_6010C20_0000C00 DCBM |
Energy | 600 A | External DC Unipolar 12 to 48 |
Other Communication |
||
| DCBM_N1D_6000C20_0000C00 DCBM |
Energy | 600 A | External DC Unipolar 12 to 48 |
Other Communication |
||
| DCBM_N1D_6000C15_0000C00 DCBM |
Energy | 600 A | External DC Unipolar 12 to 48 |
Other Communication |
||
| DCBM_N1D_4010C20_0000C00 DCBM |
Energy | 400 A | External DC Unipolar 12 to 48 |
Other Communication |
||
| DCBM_N1D_4010C03_0000C00 DCBM |
Energy | 400 A | External DC Unipolar 12 to 48 |
Other Communication |
||
| DCBM_N0M_0810W00_0000C00 DCBM100 |
Energy | 80 A | External DC Unipolar 12 to 24 |
Other Communication |
||
| DCBM_N0M_0800W00_0000C00 DCBM100 |
Energy | 80 A | External DC Unipolar 12 to 24 |
Other Communication |
||
| DCBM_N0D_4000C03_0000C00 DCBM |
Energy | 400 A | External DC Unipolar 12 to 48 |
Other Communication |
||
| DCBM_N00_6010C20_0000C00 DCBM |
Energy | 600 A | External DC Unipolar 12 to 48 |
Other Communication |
||
| DCBM_N00_6000C35_0000C00 DCBM |
Energy | 600 A | External DC Unipolar 12 to 48 |
Other Communication |
||
| DCBM_N00_6000C25_0000C00 DCBM |
Energy | 600 A | External DC Unipolar 12 to 48 |
Other Communication |
||
| DCBM_N00_6000C20_0000C00 DCBM |
Energy | 600 A | External DC Unipolar 12 to 48 |
Other Communication |
||
| DCBM_N00_4010C20_0000C00 DCBM |
Energy | 400 A | External DC Unipolar 12 to 48 |
Other Communication |
||
| DCBM_N00_4000C35_0000C00 DCBM |
Energy | 400 A | External DC Unipolar 12 to 48 |
Other Communication |
||
| DCBM_N00_4000C20_0000C00 DCBM |
Energy | 400 A | External DC Unipolar 12 to 48 |
Other Communication |
||
| DCBM_N00_0810W00_0000C00 DCBM100 |
Energy | 80 A | External DC Unipolar 12 to 24 |
Other Communication |
||
| LV 25-P/SP8 LV25 |
Voltage | 0.0067 A | 0.8 | External DC Bipolar 15 to 15 |
Current 25 mA |
|
| LV 25-P/SP7 LV25 |
Voltage | 0.008 A | 0.8 | External DC Bipolar 15 to 15 |
Current 25 mA |
|
| LV 25-P/SP6 LV25 |
Voltage | 0.0101 A | 0.8 | External DC Bipolar 15 to 15 |
Current 25 mA |
|
| LV 25-P/SP17 LV25 |
Voltage | 0.0066 A | 0.8 | External DC Bipolar 15 to 24 |
Current 50 mA |
|
| LV 25-P/SP15 LV25 |
Voltage | 0.00833 A | 0.9 | External DC Bipolar 12 to 15 |
Current 25 mA |
|
| LV 25-P/SP11 LV25 |
Voltage | 0.005 A | 0.8 | External DC Bipolar 15 to 15 |
Current 25 mA |
|
| LV 25-P/SP10 LV25 |
Voltage | 0.1 A | 0.8 | External DC Bipolar 12 to 15 |
Current 25 mA |
|
| LV 100/SP82 LV100 |
Voltage | 0.04 A | 1.5 | External DC Bipolar 12 to 18 |
Current 40 mA |
|
| LV 100/SP81 LV100 |
Voltage | 0.01 A | 0.7 | External DC Unipolar 15 to 15 |
Current 50 mA |
|
| LV 100/SP80 LV100 |
Voltage | 0.21 A | 0.7 | External DC Bipolar 15 to 24 |
Current 39.4 mA |
|
| LV 100/SP72 LV100 |
Voltage | 0.01 A | 0.7 | External DC Bipolar 12 to 18 |
Current 100 mA |
|
| LV 100/SP71 LV100 |
Voltage | 0.01 A | 0.7 | External DC Bipolar 15 to 24 |
Current 50 mA |
|
| LV 100/SP69 LV100 |
Voltage | 0.025 A | 0.7 | External DC Bipolar 15 to 24 |
Current 50 mA |
|
| LV 100/SP67 LV100 |
Voltage | 0.01 A | 0.7 | External DC Bipolar 15 to 15 |
Current 50 mA |
|
| LV 100/SP58 LV100 |
Voltage | 0.1 A | 0.7 | External DC Bipolar 12 to 18 |
Current 100 mA |
|
| LV 100/SP51 LV100 |
Voltage | 0.01 A | 1 | External DC Bipolar 15 to 24 |
Current 50 mA |
LEM manufactures a wide range of products ensuring electrical measurement in several applications.
LEM product catalog contains thousands of components guaranteeing the safety and the reliability of our customers’ systems. Among these LEM products, you will find current sensors, voltage sensors, Current sensor ICs, Rogowski coils and also energy meters; relying on LEM’s Hall Effect sensor, Fluxgate and air-core technologies expertise.
With the product list above, you will be able to filter our components based on technical data such as the electrical measurement type (current measurement, energy, power supply, voltage), the sensor nominal value, the supply voltage, the mounting type, the accuracy…
If you already have in mind the LEM product series you are looking for, you can select it directly from the dropdown list. You will then have access to every component that is part of the selected product series.
Application research is also available on the product list. By choosing an application domain, you will be able to access the list of products that can be used specifically in your area of choice, be it battery management system, automotive motor control, EV chargers, traction, trackside, automation, power supplies, welding, drives, high precision, renewable energy or smart grid.
While browsing on our product list, you will also have the possibility to download product material and get access to datasheets, 3D and user guides.
In short, by filtering out electronic components with that tool you will be able to narrow the research to the current sensor that will specifically answer your needs, matching your application domain and your technical specifications while getting access to valuable product documentation.