HOxx-PW-

Contactless current transducers for DC, AC and pulse currents measurements of 4 ranges: 100 ARMS, 150 ARMS, 200 ARMS, 250 ARMS. Overcurrent detection on a dedicated pin, Digital output: 2 wire CMOS or 2 wire RS422 Manchester or 2 wires LVDS Manchester or 4 wire LVDS or 4 wire RS422. Small design (22 (W) x 43 (L) x 30 (H)), Creepage & clearance distances: 8 mm + CTI 600. PCB mounting with aperture for the primary conductor (15 x 8 mm).

Model details

HO 200-PW-0100

200 A RMS nominal, 2 Wires RS422 Manchester digital output

Series
HOxx-PW-
Measurement
Current
Nominal Value
200 A
Measuring Range
500 A
Second. Nominal Signal
Other
Second. Nominal Signal Value
Instantaneous Pulse Density Modulation (PDM)
Primary Signal
AC + DC
Supply Voltage
External DC Unipolar
Supply Voltage Range
5 - 5 V
Accuracy
1.5 %
Op. Temperature
-40 °C / 105 °C
Technology
Open loop Hall effect
Mounting
PCB
Applications
Automation
Drives
Power Supplies
Renewable Energies
Welding
HO 200-PW-0100
PICTURE
FRONT
BACK
LEFT
RIGHT
Download

Relative information

Order

Contact Information

Series

Product of the same series